Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

安全光栅


Narrow down search result list

产品选型工具结果: 258 产品

分辨率

光束数量

保护区域高度

最大检测范围

操作模式

安全输出

连接类型

安全类型

安全完整性级别

性能水平


Choose your product


Next PageLast Page
产品
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Slim design, mounting on three sides, Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m
, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mm
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 60 mm , Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 90 mm, Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 14 mm (finger protection), Protection field height up to 1200 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 1200 mm
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 60 mm , Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Resolution 90 mm, Protection field height up to 2400 mm, Self-testing (type 2 as per IEC/EN 61496-1), SIL1 acc. to IEC 61508, Temperature range -30 ... 60°C (-22 ... 140 °F), Connection: Transmitter unit: 4-pin, M12 x 1 connector
Receiver: 8-pin, M12 x 1 connector
Cable cross section min. 0.25 mm2
Max. cable length 50 m, Operating mode: Startup/restart disable, deactivateable, Protection field height: see Table 1, max. 2400 mm
Reset button, M12 plug connection, Connection: M12 x 1 connector , 4-pin
Deflecting mirror for multi-sided protection safety layouts using SLC series safety light grids
Next PageLast Page