Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

信号中继安全栅


Narrow down search result list

产品选型工具结果: 23 产品

场侧

控制侧

传输方向

电源

特殊

防爆


Choose your product


Next PageLast Page
产品

1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC, Explosion protection: Ex-Input, Field side connection: Resistance, Control side connection: Resistance, Transfer direction: to the control systempa

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508pa

1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Rated voltage: 19 ... 30 V DC, Explosion protection: Ex protection, Field circuit: 0-20 V, Safe area: 0-20 Vpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC, Explosion protection: Ex-Input, Field circuit: Resistance, Safe area: Resistance, Transfer direction: to the control systempa
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508pa
1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the control systempa
1-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA ... 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508pa
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL3 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Input, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508pa
2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508pa
Next PageLast Page
Download the compendium on Functional Safety

Free PDF Download: Compendium Functional Safety

Download our free PDF compendium on Functional Safety and learn more about the specific standards and methods of risk reduction. We also show you how to implement safety equipment and provide you with a helpful glossary for your daily work.